Products
  • ADX-2500 X-ray Diffraction Instrument

    VIEW MORE+
  • ADX-2700 X-ray Diffraction Instrument

    VIEW MORE+
  • ADX-8000 Portable X-ray Diffraction Instrument

    VIEW MORE+
  • ADX-9800 Energy Dispersive X-Ray Fluorescence Spectrometer

    VIEW MORE+
  • AA XRF Handheld Portable Energy Dispersive X-ray Fluorescence Spectrometer

    VIEW MORE+
X-ray Diffractometer and X-ray Flaw Detector

ADX-9800 Energy Dispersive X-Ray Fluorescence Spectrometer

Inquiry and Sales: sales@angstrom-advanced.com or Online Request

Introduction

The ADX9800 is a powerful EDXRF that has built in multiple collimators and for the various testing parameters. The vacuum chamber allows for highly precise results and the ability to test elements from Sodium (Na) to Uranium (U).

Hardware

Si-Pin/SDD Detector Ultra High Resolution Detector

  • Electro-refrigeration semiconductor detector with energy resolution: 130eV
  • Energy response range: 1-50 keV
  • Be window thickness: 50 μm
  • It is used to detect the characteristic X-rays of the samples, and then collect the information and amplify it.

X-ray Tube

  • Service life is more than 20,000 hours
  • Emitting X-rays towards the samples
  • Target: Mo/Ag (please ask Angstrom for your application)

High/Low Voltage Power Supply

  • Tube Voltage: 5~50kV
  • Tube Current: 5μA - 1000μA
  • Supplying exclusive power to X-rays tube
  • Voltage regulation/adjustment rate: 0.01% (from zero load to full load)
  • Voltage stability of 8 hrs: 0.05%

Multi-Channel Analyzer

  • It is used to conduct data processing of the collected information, and transfer the results to the computer.

High Resolution Camera

  • In-Built High Resolution Camera for Sample Observation and Placement.

Vacuum system

  • Provide vacuum condition for the samples during the test. Vacuum degree reaches 10-2 Pa in 10 second. High vacuum area reaches 10-1 – 10-5 Pa.

Automatic Switch between Collimators/Filters

Software

Functions: RoHS Analysis, Full Element Analysis and Plating Thickness Analysis.

  • It can conduct a video observation on the placement of the samples.
  • It can analyze dozens of elements simultaneously and it will only take 1 to 3 minutes.
  • It can conduct qualitative analysis automatically and report accurately.
  • It can initialize and calibrate the instrument automatically.
  • It has several analysis methods of spectral fitting.
Technical Performance and Specifications
The elements can be analyzed from the sodium (Na) to uranium (U). Analysis range of the content of elements is from 0.07 ppm to 99.999%.
Testing time: 60-300s. The measurement repeatability can reach 0.01% for total intensity of fluorescence.
The measurement repeatability can reach 0.05% for total intensity of fluorescence under the condition that the content is above 97%. Energy resolution: 130± 5eV (Ordinary).
Temperature range is from 15℃ to 35℃. Power supply: AC 110/220±5V (AC purified regulated power supply is recommended.)
Independent matrix effect correction model. Multi-variable non-linear regression procedure.
Arbitrary optional analysis and identification models. 30 elements can be analyzed simultaneously.
Thermo Electric Cooling Method; Requires NO LN2